Honeywell R8184G4009 Cad Cell Relay (45 Sec)Intermittent,120V
Honeywell R8184G4009 Cad Cell Relay (45 Sec)Intermittent,120V is backordered and will ship as soon as it is back in stock.
Couldn't load pickup availability
Delivery and Shipping
Delivery and Shipping
Fedex ground and freight. Free Shipping on everything!
Description
Description
Features:
Use in Intermittent Ignition Applications
Capable of Zone Control with Zone Valves
Circulator Zone Control with Zc and Zr Terminals on R8182D,E,H,J 8 Flame Failure During the Running Cycle Results in a 45 Second Attempt to Restart
If Unsuccessful, Safety Shut-Off Occurs, Requiring Manual Reset before Burner Can be Restarted
R8182D,E,F Mount Directly on Burner
R8182H,J Mount on 4 X 4 in Junction Box and Include 5 Foot (1.5 Meter) Armored Capillary with Remote Sensor
C554A Cadmium Sulfide Flame Detector and a 24 Volt AC Thermostat Required
Specifications:
Manufacturer: Honeywell
Manufacturer Part Number: R8184G4009
Product Type: Burner Oil Primary
Actuation Type: Electronic
Current Rating: 7.4 A @ 120 VAC and 3.7 A @ 240 VAC (Full Load), 44.4 A @ 120 VAC and 22.2 A @ 240 VAC (Locked Rotor)
Input Supply Rating: 120/240 VAC
Temperature Rating: -40 to 147 Degrees F
Media Handled: Oil
Safety Switch Timing: 15/30/45 Second
Ignition Type: Interrupted and Intermittent
Mounting Type: Junction Box
Connection Type: Burner Motor/Oil Valve/Ignition/Cad Cell/Limit/Thermostat/Alarm
Dimensions: 4.9" x 4.4" x 3.45"
Weight: 1.32 lb.
Includes: Selectable Valve and Blower Delay, 2-Line LCD Display